Heat Pump SCOP, Flow Temperature (35C vs 55C), and the Spark Gap
Why lowering radiator flow temperature boosts real heat pump efficiency and how the electricity-to-gas price ratio decides payback.
Carnot physics and Fraunhofer ISE field measurements
An air-to-water heat pump moves heat from cold outdoor air into your home's water loop. The smaller the temperature lift, the higher its Seasonal Coefficient of Performance (SCOP). In Fraunhofer ISE's 2024 field study of 61 air-to-water heat pumps installed in existing buildings, measured seasonal performance averaged 3.4 across a range of 2.6 to 4.9. Pure underfloor heating at 35C flow approaches 3.9, well-sized radiators at 45C average around 3.4, standard 55C radiators run near 2.9, and legacy 65C systems sink toward 2.4. Ground-source heat pumps typically add about +0.7 SCOP.
The cold-week test and the Spark Gap rule
Before signing a heat pump quote, run your existing gas or oil boiler at 45C or 50C flow temperature during a cold winter week. If every room stays warm, your existing radiators are ready; if one room lags, upgrading a single oversized radiator in that room is often worth more than any tariff tweak. On running cost, divide your electricity price by your gas price to get the Spark Gap (for example, 0.30 / 0.143 = 2.10 in Switzerland). A heat pump costs less to run than a condensing gas boiler (90% efficiency) whenever its real SCOP exceeds Spark Gap x 0.90.
Compare against a new boiler when yours is aging
If your gas boiler is 15 to 20 years old, you are not comparing a heat pump against zero cost: you are comparing it against buying a replacement boiler. Subtracting avoided boiler replacement cost and national subsidies (such as Slovakia's Zelena domacnostiam II at 400 EUR/kW up to 4,000 EUR, or the UK Boiler Upgrade Scheme) shows the true incremental payback.
Worked radiator upgrade vs. tariff example
Consider an existing detached house needing 18,000 kWh of space and water heat per year at 0.30/kWh electricity versus 0.14/kWh gas (Spark Gap 2.14). Running at 55C radiator flow (SCOP ~2.9) draws 6,207 kWh of electricity per year (1,862 in annual running cost). Upgrading two undersized living-room radiators to double-convector Type 22 or Type 33 panels so the whole circuit runs at 45C flow raises field SCOP to ~3.4, cutting electricity draw to 5,294 kWh per year and saving 274 every winter thereafter. Remember also that rooftop solar covers at most 10 to 25% of winter heating electricity at mid-latitudes because space heating peaks in December and January when solar output is lowest; never trust a brochure promising 60% solar heating coverage.