The 24/7 Rule: Every 10 Watts Continuous Equals 87.6 kWh Per Year
How to hunt down old garage freezers, 24/7 homelab servers, espresso boilers, and towel rails burning hundreds silently.
Short high-watt bursts matter far less than continuous medium loads
Households often worry about brief 2,200W kettle boils (~160 kWh/yr) while overlooking a 15-year-old garage chest freezer (570 kWh/yr), an electric towel rail left running continuously, or a 45W dual-boiler espresso machine kept hot all day. Multiply continuous watts by 8.76 to get annual kWh immediately.
Measure it yourself with a plug-in power meter
Nameplate labels show peak watts, not average duty cycle. A 15 to 25 EUR plug-in energy meter (or a Shelly/Home Assistant smart plug) left on a fridge or freezer for 72 hours reveals exact real kWh/yr and lets you check payback before replacing any appliance.
How to run a 20-minute night baseload audit
If you have a smart-meter CSV, check your median consumption between 01:00 and 04:00 local time on McKwh's My Meter Data page. An efficient apartment with one modern refrigerator and a router idles around 80 to 130 W (700 to 1,140 kWh/yr). If your night baseload exceeds 250 W (2,190 kWh/yr, costing roughly CHF 655/yr in Switzerland or EUR 817/yr in Germany), inspect five usual suspects in order: old circulation pumps on legacy heating systems (40-80 W each), always-on NAS or desktop PCs (35-90 W), secondary garage fridges or beer coolers (40-70 W average), ventilation units stuck on boost mode, and electric underfloor bathroom mats left on summer thermostats. Cutting 100 W of continuous phantom load saves 876 kWh every single year forever.