Why 8,760-Hour Solar & Battery Math Exposes Inflated Sales Quotes
Monthly averages hide the winter-vs-summer mismatch and inflate battery savings. Here is how hour-by-hour simulation reveals the truth.
The annual-average illusion
Many solar sales brochures compare your annual electricity consumption (say 5,000 kWh) against annual solar production (6,500 kWh) and imply you will barely pay for grid power again. At mid-latitudes (45-55 degrees North) on an optimal tilt roof, July delivers roughly 3 to 5 times more solar energy than December (for example, PVGIS 5.3 measures 3.5x in Dietikon ZH, 3.6x in Bratislava, and 4.6x in Kassel), while household heating and lighting demand peaks in winter. Without an hour-by-hour 8,760-hour dispatch model, you cannot see how much summer midday electricity overflows into low-value exports while winter evenings still pull from the grid.
Evaluating the battery incrementally, never bundled
Always separate your solar quote into two numbers: panels-only payback versus the extra money saved solely by adding the battery. At realistic 2026 installation prices, a panels-only rooftop array typically pays back in roughly 10 to 15 years in Slovakia or Switzerland (faster in high-tariff markets like Germany or high-sun Spain). Adding a 10 kWh battery raises self-sufficiency, saving roughly 1,100 to 1,800 extra kWh of grid imports per year after round-trip and standby losses. Multiply those extra kWh by your import-minus-export spread, then multiply by the battery warranty (usually 10 to 12 years): that gives the break-even battery price you should negotiate around.
Why quarterly feed-in rates matter in Switzerland and Europe
When utilities pay quarterly reference prices (such as EKZ in Zurich paying 10.27 Rp in Q1, 3.90 Rp in Q2, and 8.54 Rp in Q3, with a 6.00 Rp minimum under 30 kW), summer midday exports earn far less than winter exports. Modeling a single flat export price hides how little surplus summer power earns and misstates the true value of self-consumption.
Worked kitchen-table quote audit checklist
Take any installer proposal and run four fast checks before signing. First, divide the panels-only turnkey cost (excluding storage) by system kWp and compare against regional median prices; anything far above the 75th percentile needs an itemized explanation such as steep scaffolding or slate roofing, while an unusually cheap offer below the 25th percentile often omits inverter commissioning, meter upgrades, or surge protection. Second, check whether the quote assumes 3 to 5% annual electricity price inflation to shrink payback on paper; always verify the payback at 0% drift using today's confirmed tariff first. Third, confirm whether inverter replacement around year 13 and battery replacement around year 12 are included in any 20-year profit figure. Fourth, if you already have a smart-meter CSV, replay your exact hourly consumption instead of a generic curve so your evening load and winter baseline are represented accurately.